MED-210 IPL Hair Removal Machine

Product presentation · Confirm configuration with your quotation

KES / Hair removal

MED-210 IPL Hair Removal Machine Manufacturer

MED-210 is an IPL hair removal machine with a published HR spectrum of 640–1200nm, pulse-control entries and a dedicated equipment specification. Review the configuration and installation questions before requesting a manufacturer quotation for your destination.

View specifications ↓
For distributors and professional procurement.
Share your destination market when you enquire.
Know your configuration

Technical specifications

MED-210 · Published configuration
Wavelength (Spectrum)640-1200nm(HR)
Energy Density (Fluence)10-60J/cm2
Spot Size15*50mm2 (HR)
Pulse Repetition Rate0.2Hz; 2Hz
Pulse Duration0.5-15ms
Pulse Delay1-50ms
Pulses1-15 pulses
IPL Peak Power1400W
CoolingContinuous Crystal contact cooling (-4℃~4℃ ) + Air cooling + Closed water circulation cooling
Stand-by WorkingContinuously for 12 hours
Display8.4″ True Color LCD Touch Screen
Electrical Requirements100-240VAC, 20A max., 50/60Hz
Net Weight27 kgs
Dimensions (WxDxH)52*60*37cm

Options and order-specific details should be confirmed in the final quotation.

01

An IPL model with its own specification record

MED-210 is the product reference for this IPL hair removal machine. Start with that model name when requesting specifications or comparing an offer. The published record provides an HR spectrum, energy-density range, pulse settings, cooling description, display and physical requirements. These entries support a procurement review without establishing an individual treatment plan or guaranteeing an outcome.

If your organization already has IPL equipment, identify the requirements that matter for a replacement or additional unit. Do not assume accessories, controls or maintenance procedures are compatible simply because two machines use the same broad technology. Ask about the exact equipment package proposed for MED-210, including the handpiece and accessories that would be supplied with the order.

For a distributor, the model-specific record also provides a clear basis for preparing a product listing. Keep the HR configuration separate from unconfirmed alternatives and avoid borrowing capabilities from other products in the category. Your initial inquiry can name the intended market, customer type and outstanding technical questions so the quotation discussion focuses on the machine you actually want to evaluate.

02

HR spectrum and the scope of the configuration

The published wavelength entry identifies a spectrum of 640–1200nm and marks it HR. Retain that qualification when describing the machine. A spectral range is not a single laser wavelength, and it should not be rewritten as one. The purchasing question is which configuration and components correspond to the HR entry in the proposed equipment package.

Ask for the exact supplied handpiece and optical components to be identified in the quotation. If your plan calls for a different filter or accessory, describe it as a separate requirement and request confirmation. Do not treat other configurations discussed informally as automatically included in the standard offer. The final equipment schedule should allow your team to see what is supplied without interpreting a collection of marketing photographs.

The listed spot-size entry is 15 × 50mm² for HR. Keep that entry attached to the HR configuration rather than extending it to an unconfirmed accessory. If the technical definition or physical dimensions need clarification for your comparison, ask for it directly. A spot description alone does not establish appointment time, patient suitability or the quantity of work a facility can safely schedule.

03

Energy density and pulse timing belong in separate fields

MED-210 lists energy density as 10–60J/cm². Its pulse-duration entry is 0.5–15ms, pulse delay is 1–50ms and the pulse-count entry is 1–15 pulses. These values describe different controls or equipment properties. They should remain separate in a technical comparison rather than being collapsed into one broad claim about power or performance.

The repetition-rate entry lists 0.2Hz and 2Hz. Preserve those stated values without assuming a continuous range or every intermediate setting. If your evaluation depends on how a control is selected or which settings can be combined, request the current instructions and an explanation for the offered configuration. A website table is not sufficient to define an operating sequence or clinical protocol.

Ask your equipment reviewers to record both the stated values and the questions they raise. For example, which control is available in the selected mode, which labels appear on the interface and what conditions apply to the listed limits? Obtaining those answers is more useful than choosing equipment by the highest setting alone. None of these specifications establishes a guaranteed hair-removal result or suitability for every individual.

A technical comparison is easier to review when duration, delay and pulse count have separate rows. Ask the person assessing the equipment to mark which entries are essential to the purchase and which need further explanation. Keep the units visible, since a timing value should not be compared directly with a frequency or energy-density value. If a demonstration uses a particular combination, request its documentation context rather than treating the demonstration as evidence that every combination is available. The outcome of this review should be a clearer equipment specification, not an operating protocol assembled from isolated catalog numbers.

04

Peak power and cooling description

The published IPL peak-power entry is 1400W. Keep the word peak with that value. It should not be substituted for an average output, a complete electrical requirement or a measure of the result a person will receive. If your purchasing analysis requires a different power quantity, request the relevant specification instead of inferring it from the peak figure.

The cooling description combines continuous crystal contact cooling, air cooling and closed water-circulation cooling. The contact-cooling entry lists minus 4°C to plus 4°C. These are equipment specifications, not a statement that the skin or tissue reaches that range and not a promise of a painless procedure. Ask for the operating conditions and care instructions applicable to the supplied unit.

Maintenance questions should cover the cooling arrangement as a whole. Request the preparation requirements, permitted materials and the distinction between routine care and qualified technical work. Ask how any required maintenance items are identified and obtained. Do not assume that a closed circulation description eliminates maintenance, or that instructions from a different IPL machine can be carried over without confirmation.

05

Display, dimensions and site preparation

The listed display is an 8.4-inch true-color LCD touchscreen. If interface language or a particular control presentation is important to your organization, put it in the purchasing brief and ask for confirmation. A display-size entry does not establish every software feature, saved program or access-control capability that a buyer might expect from another machine.

The equipment dimensions are listed as 52 × 60 × 37cm in width, depth and height, with a net weight of 27kg. These values give a starting point for placement planning. Request the full installation information, including the space needed for handpiece handling, ventilation and maintenance. The machine dimensions do not determine a suitable support surface or room arrangement by themselves.

Electrical requirements are listed as 100–240VAC, 20A maximum and 50/60Hz. Have the ordered configuration confirmed and provide the current requirements to the qualified person reviewing your site. Do not treat a catalog voltage range as a complete installation instruction. It is better to resolve electrical and placement questions during procurement than to discover an unresolved requirement when the equipment arrives.

06

Build an IPL comparison that stays model-specific

A practical comparison sheet for MED-210 can have separate headings for the HR configuration, pulse entries, cooling, included components, installation requirements and commercial terms. Use the same headings for any alternative you are considering, but do not fill an empty field with a number from another machine. Ask for missing information and preserve the labels used by each specification.

The standby-working entry lists continuous for twelve hours. It does not define a guaranteed treatment schedule, a number of appointments or an absence of maintenance. If operating conditions are important to your purchasing review, request the information needed to understand that entry. Plan staffing and commercial expectations independently of unverified calculations based on a standby figure.

Ask how replacement handpieces and related items would be identified for a future inquiry. Clarify whether a proposed spare, maintenance material or accessory is included or separate. For a distributor, this helps define the equipment package you will describe to your customers. For a facility, it supports a clearer equipment record and purchasing process without assuming that every component pictured in promotional material is part of the base order.

07

Quotation, OEM discussion and delivery handover

To request an offer, identify MED-210, your destination country, anticipated quantity and any required accessories. Explain whether the purchase is for distribution or your own professional setting. If you want OEM or ODM changes evaluated, describe the branding, packaging or language requirements separately from the technical configuration and ask about feasibility, approval steps, quantity requirements and cost.

Request the model-specific documents needed for your destination and have their relevance assessed where appropriate. Equipment naming and a published specification do not establish permission for every market or every application. This product page does not promise permanent results, universal suitability or a clinical outcome. Keep the documentation request tied to the exact machine and intended lawful professional use.

For delivery, request packed dimensions and gross weight rather than relying on the net machine figures. Clarify freight, unloading and positioning responsibilities, then ask which training or handover arrangements are available for your location. Request written warranty coverage and a technical-support process, including any limitations affecting handpieces, wear items or transport costs. A complete offer should make the equipment package and the responsibilities surrounding it equally clear.

Before you enquire

Questions, answered.

What spectrum is published for MED-210?

The HR entry lists 640–1200nm. It is a spectrum rather than a single laser wavelength. Ask for the supplied HR configuration and optical components to be identified in the quotation, and confirm any different accessory requirement separately.

Can I assume the repetition rate is adjustable across all values?

The published entry lists 0.2Hz and 2Hz. It is not expanded here into a continuous range. Request the current operating information if the available control steps or combinations are important to your technical evaluation.

Does 1400W describe the electrical supply requirement?

It is labeled IPL peak power in the record. Do not use it as a substitute for installation requirements or another power quantity. Request the electrical documents for the ordered unit and have the proposed site assessed by qualified personnel.

What does the contact-cooling temperature mean?

Minus 4°C to plus 4°C is the published contact-cooling entry. It is not a tissue-temperature measurement or a promise about sensation or outcome. Ask for the conditions and instructions that apply to the actual equipment configuration.

What should be included in the final purchase description?

The full model name, HR configuration, supplied handpiece and accessories, electrical requirements and agreed commercial terms should be identifiable. Confirm any options separately and ask for delivery, handover, warranty and technical-support responsibilities to be stated in writing.

Keep exploring

In the same collection.

Explore category →
Your next equipment project

Let’s build your shortlist.

Tell us your market, preferred model and configuration questions.

Discuss your requirementsChat on WhatsApp ↗
WhatsApp ↗